NLS Power
Cast-Resin Transformers

Cast-Resin Transformers

Cast-resin transformers encapsulate the windings in epoxy resin under vacuum, a dry-type construction that resists moisture and dust without a separate enclosure. NLS Power sources and supplies cast-resin units built to IEC 60076-11 for hospitals, data centres, metro stations and coastal or dusty sites across Saudi Arabia where a conventional dry-type winding would need extra protection.

Cast-resin transformers are a specific construction within the dry-type family: the windings are encapsulated in epoxy resin under vacuum, which fills every void around the conductor rather than leaving it exposed to air the way a standard VPI dry-type winding does. The result is a winding that resists moisture ingress, dust settlement and condensation on its own, often reaching an IP54-equivalent level of protection without adding a separate cabinet or forced ventilation.

That property matters on two kinds of Saudi sites. Coastal installations near Jubail, Yanbu or the Eastern Province deal with salt-laden humid air that condenses on cooler surfaces overnight, a condition that can degrade an unprotected dry-type winding's insulation over years of cycling. Dusty inland sites, industrial yards and semi-outdoor plant rooms present the opposite problem: fine particulate settles on windings and creeps into ventilation paths. Cast-resin construction handles both without the added mechanical enclosure a standard dry-type unit would need to reach the same protection level.

IEC 60076-11 covers cast-resin the same way it covers other dry-type constructions, including the F1, F0 or F2 fire behavior classification that rates how the resin performs under direct flame exposure, a distinction worth confirming against the project's fire engineering brief since not every cast-resin product is self-extinguishing to the same standard. Cooling still follows AN or AF classes, and vector group is typically Dyn11 for SEC-connected distribution duty, same as other dry-type transformers.

Hospitals, data centres, metro stations and any building where reliability and low maintenance matter more than upfront cost tend to specify cast-resin over standard VPI dry-type for this reason. NLS sources and supplies cast-resin transformers against the rating, fire classification and cooling class a project's spec and SEC connection approval require.

Specifications

  • ✓Winding: epoxy resin encapsulation under vacuum casting, no oil, per IEC 60076-11
  • ✓Environmental resistance: near IP54-equivalent protection against moisture and dust without a separate enclosure
  • ✓Fire behavior: F1 self-extinguishing classification available, confirm against project fire engineering brief
  • ✓Cooling classes: AN (natural air) standard, AF (forced air) for a higher rating on the same frame
  • ✓Vector group: Dyn11 standard for SEC-connected LV distribution
  • ✓Typical use: hospitals, data centres, metro stations, coastal and dusty industrial sites

Frequently Asked Questions

What's the difference between cast-resin and standard dry-type transformers?+

Both are oil-free, but cast-resin windings are encapsulated in epoxy under vacuum, filling the space around the conductor completely, while a standard VPI dry-type winding is coated but still exposed to ambient air. That encapsulation gives cast-resin units better resistance to moisture and dust without needing an extra protective enclosure.

Where does cast-resin construction matter most in Saudi Arabia?+

Coastal sites near Jubail, Yanbu and the Eastern Province, where humid salt-laden air condenses on equipment overnight, and dusty inland industrial yards, where fine particulate settles on standard windings over time. Cast-resin handles both without the added mechanical protection a standard dry-type unit would need.

Is a cast-resin transformer more expensive than a standard dry-type unit?+

Generally yes, the resin encapsulation process adds cost over standard VPI dry-type winding, but it removes the need for extra environmental protection or more frequent maintenance in humid or dusty conditions, which is the tradeoff most Saudi specs for hospitals and data centres are willing to make.

Related products

Package Substations

Package Substations

A package substation combines MV switchgear, a transformer and an LV panel inside one factory-built, weatherproof enclosure, delivered to site as a single tested unit rather than assembled from separate equipment. NLS Power sources and supplies package substations built to IEC 62271-202 for compounds, labor camps, retail and industrial sites across Saudi Arabia, reducing on-site civil and electrical work.

Unit Substations

Unit Substations

A unit substation assembles MV switchgear, transformer and LV switchboard as coordinated equipment for a building's own electrical room, rather than a free-standing outdoor kiosk. NLS Power sources and supplies unit substations for high-rise towers, hospitals and industrial plants across Saudi Arabia, engineered so protection settings between the MV and LV sides are coordinated before equipment reaches site.

Ring Main Units (RMUs)

Ring Main Units (RMUs)

A ring main unit is a compact MV switchgear panel, usually three-way, that loops a medium voltage ring between substations so a fault on one section can be isolated without cutting power to the rest of the loop. NLS Power sources and supplies RMUs built to IEC 62271-200 for compound, industrial park and campus distribution networks across Saudi Arabia.

Auto-Transformers

Auto-Transformers

An auto-transformer shares a single winding between primary and secondary instead of using two fully isolated windings, which makes it smaller, lighter and lower-loss than a two-winding transformer of the same rating for a modest voltage change. NLS Power sources and supplies auto-transformers built to IEC 60076-1 for voltage step and interconnection duty on Saudi transmission and industrial projects.

Transformer Protection Relays

Transformer Protection Relays

Transformer protection relays detect internal and external faults, differential, restricted earth fault, overcurrent and temperature, and trip the transformer's circuit breakers before a fault causes structural damage or spreads to the wider network. NLS Power sources and supplies numerical protection relays with IEC 61850 communication for transformers on SEC-connected and industrial substations across Saudi Arabia.

Dry-Type Transformers

Dry-Type Transformers

Dry-type transformers use air or resin-insulated windings instead of oil, which makes them the standard choice for basements, hospitals, high-rise risers and any indoor room where fire load and oil containment are a concern. NLS Power supplies dry-type units built to IEC 60076-11, in AN and AF cooling classes, sized to the vector group and rating an SEC connection requires.

Available in

Get in touch

Send us your RFQ

Tell us what you need and we will come back with pricing and lead times.

+966 53 590 8101