Power Quality
NLS Power supplies voltage stabilizers, automatic voltage regulators, power factor correction banks, harmonic filters, surge protection, power quality analysers and isolation transformers for Saudi facilities dealing with SEC power factor penalties, IEEE 519 limits or unstable supply.
Power quality problems rarely announce themselves. Equipment fails earlier than it should, protection trips for no obvious reason, transformers run hot, and the electricity bill carries charges nobody can explain. The causes are usually measurable and fixable.
Power factor is the most direct. Motor and inductive loads draw reactive current that does no useful work but still has to be delivered, and SEC applies penalties when power factor falls below the threshold. Correction banks sized against the actual load profile raise the power factor above that line, and in motor heavy facilities this equipment usually pays back faster than any other electrical improvement.
Harmonics are the subtler problem. Variable speed drives, UPS rectifiers and IT power supplies draw current in pulses rather than smoothly, and the resulting distortion overheats transformers and neutral conductors, causes nuisance tripping and can put a facility outside IEEE 519 limits. Harmonic filters address it, and a power quality analyser is what tells you which order of harmonic you are actually dealing with rather than guessing.
Voltage stability matters at the end of long feeders and on remote sites, where voltage drop and fluctuation stress equipment. Stabilizers and AVRs hold output within tolerance.
Surge protection under IEC 61643 is the cheapest insurance in the electrical package, protecting against both lightning transients and switching surges from within the installation.
NLS Power supplies stabilizers, AVRs, PFC banks, harmonic filters, surge protection devices, power quality analysers and isolation transformers.
Related products
Frequently Asked Questions
How do we stop power factor penalties on the SEC bill?+
Install power factor correction sized against the actual load profile so the measured power factor stays above the penalty threshold. A power quality survey first confirms the size needed rather than guessing.
What causes nuisance tripping and hot transformers?+
Often harmonic distortion from variable speed drives and rectifier loads. The distorted current overheats transformers and neutrals and can trip protection with no obvious fault. A power quality analyser identifies which harmonics are present before choosing a filter.
Is surge protection worth fitting?+
Yes. It is inexpensive relative to the equipment it protects, and it covers switching transients from inside the installation as well as lightning, which are more common than most people expect.